Guide
How to size a sauna heater
The short version
Measure the hot room
Measure the inside of the finished hot room. For a rectangular room, take length, width and height. If the ceiling slopes, use the average height. For a barrel, measure inside length and inside diameter.
Work out the measured volume
Multiply length by width by height. For a barrel, use π times the radius squared times the length. Leave the benches, the heater and the stones in the measurement.
Apply the log factor when it fits
If the interior walls are solid uninsulated logs, multiply the measured volume by 1.5. Do not also type those log walls into the stone or tile area.
Add uninsulated surfaces
Add 1.2 cubic metres for every square metre of glass, stone, tile, brick or similar uninsulated surface.
Read an electric heater from that volume
Treat 1 kW per adjusted cubic metre as the minimum. Choose a model whose published room range puts that volume near the middle, not on the edge.
Read a wood stove from the same volume
Match the adjusted volume to the stove's published room range. A wood stove's nameplate kilowatts are a different scale from an electric heater.
A heater that is too small for the room runs flat out and still struggles to get there. A wood stove that is far too large for a small room is hard to keep pleasant. The figure to start from is the volume of the hot room, adjusted for the surfaces that soak up heat, compared with the room range printed in the heater manual.
The calculator on this site does the arithmetic. This page is the method, so you can see what it is doing. It follows the guidance Harvia publishes for electric heaters and for wood-burning heaters.
Measure the hot room
Measure the inside of the finished room, in metres. Include the air above the benches. Leave the benches, the heater and the stones inside the measurement. Subtracting them makes the room look smaller than the volume the heater has to heat.
If the ceiling slopes, use the average height. A high ceiling holds a layer of hot air you may never sit in, and it still counts in the volume. Bench height is how you meet that hot layer. The page on how a Finnish sauna works covers that.
A barrel is a cylinder. Its volume is π × radius × radius × length, using the inside diameter and the inside length. The heater calculator has a barrel option so you can enter those two measurements directly.
Add the surfaces that drink heat
Harvia’s published adjustment is the one this site uses.
Each square metre of stone, glass, tile, brick or similar uninsulated surface counts as an extra 1.2 cubic metres. A glass door is enough to move the result. Harvia’s wood-heater note uses a door of 0.9 m by 2.1 m. That is 1.89 m². Multiplied by 1.2, it adds 2.27 m³. Their example room is 2.0 × 2.5 × 2.3 m, which is 11.5 m³, and with that door the calculated volume is about 13.8 m³. Measure your own glass. A fully glazed end on a barrel adds more than a single door.
If the interior walls are non-insulated logs, multiply the measured volume by 1.5, then add the glass and masonry. Keep the log walls out of the stone box. Counting them twice is how a sensible room turns into an oversized heater.
Insulated timber walls use the measured volume as it stands, plus whatever glass or masonry you enter. A glass door on an otherwise insulated room still counts.
Turn the volume into an electric heater
Harvia states an average of 1 kW of heater power for each cubic metre of that adjusted volume, and says the figure from this kind of calculation is, in most cases, a minimum. An undersized heater has to be heated longer and harder, which shortens its life.
Heaters are sold in steps, and each model lists a minimum and maximum room volume. Harvia’s advice is to land near the middle of a model’s range. In their published example, a calculated volume of 9.5 m³ is a poor fit for a heater listed at 6–10 m³, and a better fit for the next model, listed at 8–14 m³. The point of the example is the habit: stay off the edge of the range. The model names are theirs, from that article, and they are an illustration of how to read a chart.
This site’s calculator shows that 1 kW per cubic metre minimum, and a top of the range 25 percent higher. The 25 percent is Sauna Nerd’s planning margin, so you have room to choose a model whose published range covers you with space on both sides. It is a planning margin. The manual’s minimum and maximum cubic metres are the limit you buy against.
The supply is a separate question. The manual states what that model needs, and an electrician has to confirm the circuit. Copying a cable size from a different heater, or from a forum, is how people get this wrong. This page deliberately stops before those numbers.
Wood stoves use the same volume
Size a wood-burning heater from the same adjusted volume. Harvia tells you to do the glass and log adjustments, then pick a stove rated for that size of room. In their wood-heater article, a calculated volume of about 14 m³ is a prompt to look at a stove rated for something like 10–20 m³, near the middle of a range rather than on the end of it.
The kilowatt number on a wood stove sits on a different scale. A published reference point is the Harvia M3, listed at 16.5 kW for rooms of 6–13 m³. A large share of a fire’s heat leaves through the flue, which is why that nameplate looks high next to an electric heater for a similar room. Match the stove’s stated room volume, and read the safety clearances, before you compare kilowatts.
What the result is for
Use the adjusted volume as the number you take shopping. For an electric heater, the kilowatt range is a guide to which shelf to look at. For a wood stove, the volume is the thing to match. Then follow the manufacturer’s room limits for the exact model, including the minimum ceiling height, which many manuals set around 1.9 or 2.0 m.
Building rules for flues, and the design of an electric supply, vary between Ireland, England, Scotland, Wales and Northern Ireland. The calculator is a guide to the room. The manual, the electrician, and the local rules finish the job.
Open the heater size calculator with a 2.4 × 2.0 × 2.2 m room and that 1.89 m² door already filled in, and replace the numbers with your own.
Questions
Do the benches come out of the volume?
Leave them in. Measure the inside of the finished room, including the space the benches, the heater and the stones occupy. Harvia's method starts from that whole volume.
How much does a glass door add?
1.2 cubic metres for each square metre of glass. A door of 0.9 m by 2.1 m is 1.89 m², which adds 2.27 m³. That door is the worked example in Harvia's own wood-heater guidance.
Is the top of the calculator's kilowatt range a Harvia figure?
The bottom of the range is Harvia's 1 kW per adjusted cubic metre. The top is 25 percent higher, which is Sauna Nerd's planning margin so you can sit inside a model's published range. The manual's minimum and maximum cubic metres are the limit that counts.
Should a barrel use the log factor?
Use the log factor only when the shell is solid uninsulated log of the kind Harvia's 1.5 multiplier describes. A thin stave barrel is a different wall. Size it from the cylinder volume plus the glass, then check the heater the seller includes.